Tubular Pipe MFL Inspection

ATMFL automatic operated to externally scan and detect loss in wall-thickness of tubular/pipe.
Various Scanning Heads for multiple size of tubular/pipe
ATMFL Scanning Tool uses powerful magnet to magnetize the tubular/pipe circumference while encircling the outer diameter. Arrays of MFL sensor then scan, detecting flux leakage that occurs at areas with corrosion and wall thickness loss.

Key features

  • Flexible heads fit a range of tubular / pipe
  • Rapid screening of complete tubular / pipe work
  • Separate battery operated lightweight ATMFL Control module
  • Motorized motion
  • Battery operated no cable handling required during operation
  • Wireless transmission of data

Specification

Description Value
Principle Of Operation Magnetic Flux Leakage
Tool Size For Tubular 2 ⅜” To 6⅝”
Tool Size For Pipe 4" to 48" Dia
Detection Sensors Sensors are placed at a distance of 7 mm circumference
Minimum Detection 0.5 mm
Wall Thickness Range 4.8 Mm To 12.7 Mm
Tool Velocity Range 0.2-0.5m/sec
Data Filter Low Pass Digital Filter
Power Requirements 24v Battery
Connecting Cable Wireless
Software For Data Analysis GMAG

Detection & Sizing

(As per: API Recommended Practice 5C1)

Class Color Band Loss Of Nominal Wall Thickness (percent) Remaining Wall Thickness (Percent Minimum)
2 Yellow 0-15 85
3 Blue 16-30 70
4 Green 31-50 50
5 Red Over 50 Less than 50